tableBASE messages and codes for VTS Agent, CICS, Batch, etc.

Messages issued from the tableBASE components, such as the VTS Agent, CICS, Batch and others, vary from function to function, and are listed in the table below. These messages can usually be viewed on the JESMSGLG. Any Severe Errors (S) messages should be referred to tableBASE Customer Support. Messages are in the format DK1nnnnnA where DK1 is the prefix, followed by a five digit numeric code and an error code letter. The error code letter indicates the type and severity of the error message:

E—Error (usually indicates user error)
I—Information
W—Warning
A—Action (user action is required)
S—Severe (no further processing is possible)

Table 88. Messages and error codes for VTS Agent, CICS, Batch, etc.

Msg Code

Text

Meaning / Instructions

DK100049S

NO CMDAREA IN CALL TO TBLBASE. ABENDING.

There was no command area supplied. Ensure that a command area is supplied for the tableBASE call.

DK100100W

Unexpected non-zero return code from user exit

DK100107W

A message was truncated at 207 characters

Information only.

DK100200S

Initialization failed

DK100200S

tableBASE Initialization failed

DK100201S

tableBASE PC Server unavailable

The tableBASE PC Server is not running. It must be running in order for tableBASE to initialize in batch jobs, CICS regions, IMS regions, DB2 SPAs and VTS-TSRs.

DK100202I

tableBASE V<nnn> is initializing for <customername>

Information only.

DK100203I

tableBASE <interface> license expires on <yyyy/mm/dd>

Information only.

DK100204I

Executing in Step=<stepname>

Information only.

DK100205I

Executing in JOB Step=<stepname> PROC Step=<stepname>

Information only.

DK100206S

tableBASE PC Server does not support LOAD

Ensure the latest PC Server is running.

DK100207E

DK1TX071 not loaded; System Exits disabled

Contact DataKinetics Technical Support for assistance.

DK100207E

DK1TX072 not loaded; User Exits disabled

Contact DataKinetics Technical Support for assistance.

DK100208S

Unable to locate tableBASE GCA

Ensure the latest PC Server is running.

DK100209S

tableBASE PC Server unavailable

Ensure the latest PC Server is running.

DK100210E

Module DK1TNUCL not loaded

Contact DataKinetics Technical Support for assistance.

DK100210I

Unable to locate tableBASE GCA

Information only.

DK100211I

Unable to locate tableBASE GCA.

Information only.

DK100213E

Error in tableBASE PC server

Contact DataKinetics Technical Support for assistance.

DK100214E

Create CMA Named Token failed

Contact DataKinetics Technical Support for assistance.

DK100214E

CMA GETMAIN failed

Contact DataKinetics Technical Support for assistance.

DK100216S

$DOPC GRANDE Failed

Ensure the latest PC Server is running.

DK100217S

$DOPC Failed to Load DK1TROTB.

Check that DK1TROTB is available for an MVS LOAD.

DK100218S

$DOPC Free LX Index Failed

Contact DataKinetics Technical Support for assistance.

DK100221E

I/O ERROR:<text>

Contact DataKinetics Technical Support for assistance.

DK100222E

QSAM ERROR: FUNCTION=<xxxxxxxx>,FILE=<ffffffff>

Contact DataKinetics Technical Support for assistance.

DK100224E

I/O PROBLEM: FILE=<xxxxxxxx> FUNC=<ffffffff> RESP=<dddd> RESP2=<dddd>

Contact DataKinetics Technical Support for assistance.

DK100225W

JOB:<jobname>,ID:<userid>,TSR:<TSRname>, CMD:<cc>,TBL:<tablename>,

– WAITING <nnnnnn> SECS FOR MAPLOCK HELD BY <jobname2> <task-id>

TSR space allocation is blocked by another process accessing this TSR. <jobname2> identifies the job holding the lock and <task-id> identifies the task id of the transaction holding the lock. Cancelling the job or transaction holding the lock may free up the lock.

CAUTION:
The operator must determine if it is safe to cancel the job or transaction.
Note:
This message is usually intermittent until the tableBASE command that is blocking the access ends. If the problem persists and is happening in a VTS-TSR, contact DataKinetics Technical Support for instructions on how to alleviate the problem.

DK100226W

Please change DD TBOPTV to TBOPT

Information only.

DK100226i

Please change DD TBOPTV to TBOPT

Information only.

DK100227W

JOB:<jobname>,ID:<userid>, TSR:<TSRname>, CMD:<cc>, TBL:<tablename>,

– WAITING <nnnnnn> SECS FOR GLOBAL TCELOCK HELD BY <jobname2> <task-id>

Access to the TSR table list is blocked by another process. <jobname2> identifies the job holding the lock and <task-id> identifies the task id of the transaction holding the lock. Cancelling the job or transaction holding the lock may free up the lock.

CAUTION:
The operator must determine if it is safe to cancel the job or transaction.
Note:
This message is usually intermittent until the tableBASE command that is blocking the access ends. If the problem persists and is happening in a VTS-TSR, contact DataKinetics Technical Support for instructions on how to alleviate the problem.

DK100227W

JOB:<jobname>,ID:<userid>,TSR:<TSRname>, CMD:<cc>,TBL:<tablename>,

– WAITING <nnnnnn> SECS FOR TCELOCK HELD BY<jobname2> <task-id>

Access to the table in the TSR is blocked by another process using the table. <jobname2> identifies the job holding the lock and <task-id> identifies the task id of the transaction holding the lock. Cancelling the job or transaction holding the lock may free up the lock.

CAUTION:
The operator must determine if it is safe to cancel the job or transaction.
Note:
This message is usually intermittent until the tableBASE command that is blocking the access ends. If the problem persists and is happening in a VTS-TSR, contact DataKinetics Technical Support for instructions on how to alleviate the problem.

DK100228W

JOB <jobname> IN <VTSname> WAITING <nnnnnnnn> SECONDS TABLE ENQ <tablename>

Job is waiting for VTS-TSR table enqueue–not received yet.

DK100229W

JOB:<jobname>,ID:<userid>,TSR:<TSRname>, CMD:<cc>,TBL:<tablename>,

– WAITING <nnnnnn> SECS FOR TLBLOCK HELD BY <jobname2> <task-id>

– LIB DD:<DDname>,DSN:<DSNname>

Access to the tableBASE library is blocked by another process in the same region using the library. <jobname2> identifies the job holding the lock and <task-id> identifies the task id of the transaction holding the lock. Cancelling the job or transaction holding the lock may free up the lock.

CAUTION:
The operator must determine if it is safe to cancel the job or transaction.
Note:
This message is usually intermittent until the tableBASE command that is blocking the access ends.

DK100230I

TBOPT Processing

Information only.

DK100231I

<keyword>=<value>

Information only.

DK100232E

Invalid value

The value entered is invalid.

DK100233E

Missing keyword

A keyword is missing.

DK100234E

Invalid keyword

The keyword entered is invalid.

DK100235E

Value exceeds maximum allowed

The value provided exceeds the maximum allowed value.

DK100236E

Keyword not allowed in this environment

The parameter provided is not allowed for this interface.

DK100237E

Missing ”=”

A “=” is missing in the parameter.

DK100238E

Invalid quoted string

The string is invalid.

DK100239E

Value field too wide

The value entered is too large. Correct and try again.

DK100240E

Value less than minimum allowed

The value entered is smaller than the minimum required.

DK100241E

Missing value

There is a missing value in the parameter.

DK100242E

Keyword (or alias) previously specified

The keyword has already been specified by using another alias name.

DK100243E

Option supported only in TBOPTGEN

This parameter must be entered in the distributed source for DK1V1134 or DK1Txx34 and rebuilt. It cannot be entered in the input for the TBOPT DD card.

DK100244I

MAXNMTAB set to <nnnnnn>

Information only.

DK100245W

VTSONLY not valid with LIB entries

DK100246W

Invalid VTS prefix for LIB<nn>=<xxxxxxxx>

DK100247W

Empty value: LIB<xx> – LIB<yy>

DK100248W

LIB<xx> exceeds max allowed <mm>

DK100249W

MULTOPNX=N is not valid

DK100250I

TBOPT Parameters: (*= Parameters not taken from TBOPT input file)

Information only.

DK100251I

<keyword>=<value>.

Information only.

DK100252I

<<<<<<< TBOPT Done >>>>>>

Information only.

DK100253I

<message>

Information only.

DK100255E

HASH_LOW_DEN_LIM must be <= 2/3 HASH_HI_DEN_LIM

Reset the density limits.

DK100256I

TSRSIZE set to LDS size of <nnnnnnn>K

Information only.

DK100258I

MAXNMTAB set by preformatted LDS TSR

Information only.

DK100260I

DK1TX066 Exit Manager Initializing

Information only.

DK100262W

Exit <xxxxxxxx> not loaded and disabled

DK100263I

Exit <xxxxxxxx> is loaded and enabled

Information only.

DK100264I

DK1TX066 Exit Manager Shutdown complete

DK100265W

Exit name <xxxxxxxxxxxxxxxx> not found in current release

DK100266E

PC Service unavailable; required for VTS_TSR use

Ensure that the correct version of the tableBASE PC Server is running.

DK100270E

Insufficient storage to process strobe data; strobe suppressed.

The strobe data file has run out of space so tableBASE strobe data will be suppressed.

DK100271E

Error on CICS WRITE JOURNALNUM; Strobe logging suppressed

DK100272E

WRITE JOURNALNUM RESP=<1234>, RESP2=<1234>

DK100273E

Dynalloc of strobe report failed. Strobe suppressed.

DK100274I

STROBE=0 forced for DB2 Stored Procedure

Information only.

DK100275E

Module DK1TRSTA not found.

Contact DataKinetics Technical Support for assistance.

DK100280E

QSAM ERROR: FUNCTION=<xxxxxxxx>,FILE=<ffffffff>

Contact DataKinetics Technical Support for assistance.

DK100281E

STROBE OUTPUT SUPPRESSED

tableBASE strobe report output (for file TBTSRPT) has been suppressed due to some error in the file, possibly a file overflow. Try increasing the disk space for the strobe report output file, TBTSRPT.

DK100282E

I/O ERROR:

Contact DataKinetics Technical Support for assistance.

DK100283E

TBTSRPT spin failed. See JESlog for messages.

DK100284E

TBTSRPT test failed. See JESlog for messages.

DK100286E

SYSPRINT DD MISSING. Run terminated.

A SYSPRINT DD card is required in the job.

DK100292W

DEBUG TRACE requested but not started

Contact DataKinetics Technical Support for assistance.

DK100292E

DEBUG TRACE requested but not started

Contact DataKinetics Technical Support for assistance.

DK100293S

tableBASE must be initialized on QR TCB. Use tran TBDR TBINIT or PLTPI.

DK100295A

Specify character for PC server Named Token

DK100300S

SYSTEM FAILURE: <xxxxxxxx> Code=<cccc>/<hhhhhhhh>, Reason=<rrrr>/<hhhhhhhh>

Contact DataKinetics Technical Support for assistance.

DK100300S

Call from <xxxxxxxx> Offset <xxxx>

Contact DataKinetics Technical Support for assistance.

DK100300S

R0-R7 <xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx ….>.

Contact DataKinetics Technical Support for assistance.

DK100300S

R8-R15 <xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx ….>

Contact DataKinetics Technical Support for assistance.

DK100301S

Logic error; Dumpid <xxx> taken to TBDUMP.

Contact DataKinetics Technical Support for assistance.

DK100301S

Logic error dump taken. Dumpcode is LGIC. Dumpid is <nnnnnnnn>.

Contact DataKinetics Technical Support for assistance.

DK100302S

System ENQ limit exceeded. Task abended.

Contact DataKinetics Technical Support for assistance.

DK100303I

CLOS-VTS <VTSname> Failed. Return Code = <nnnn>

tableBASE internal processing to end its access to a VTS-TSR failed because the VTS-TSR was canceled before the task terminated. This message is informational only.

DK100310W

tableBASE TSR <nnn>% Allocated. TSR is local TSR. Owned by Job <jobname>

The series of space management algorithms used in prior levels of V6 was changed in level 8.

It now only issues a message when the TSR usage rises above a threshold and does not indicate what algorithm is being used.

Setting the TSR_WARNING_FREQ = 0 will cause all the messages to be displayed once the TSR space usage threshold is crossed from below the threshold to above it or exactly equal to it.

The default FREQ setting is 1 (i.e. only display one message per second, at the most).

Level 8 will issue this message anytime the TSR usage rises above the value in TSR_WARNING_PCT.

(The Default TSR_WARNING_PCT is 85.)

Level 8 warnings start when the usage is exactly the TSR_WARNING_PCT value or higher.

For more details refer to the TBOPT parameter settings in the tableBASE Installation Guide.

DK100311W

tableBASE TSR <nnn>% Allocated. VTS-TSR name is <vtsname>. Owned by Job <jobname>.

Same as for message DK100310W, but applies to VTS-TSR.

DK100330I

DDNAME <ddname> is not a tableBASE Release 6 format library.

Information only.

DK100331W

LIBRARY FREE SPACE MAP INCONSISTENT WITH LEFT BLOCK COUNT

DK100332I

Caching requested for DDname <ddname>. Caching not permitted on this library. Processing with no cache.

DK100340W

Old form ML mixed with use of extended ML

DK100362E

ABEND DURING UPDATE PROCESS RC=95 SC=<xx>

DK100400E

tableBASE User Error Abend <xxxx>, Reason=<dddd/hhhh>

For more information, call DataKinetics Technical Support.

DK100400E

tableBASE User Error Abend <xxxx>, Command=<xx>,<tablename>

For more information, call DataKinetics Technical Support.

DK100400E

tableBASE User Error Abend <xxxx>, TBLBASE Initializing

For more information, call DataKinetics Technical Support.

DK100400E

tableBASE User Error Abend <xxxx>, Reason=<dddd/hhhh>, Command=<xx>,<tablename>

For more information, call DataKinetics Technical Support.

DK100400E

tableBASE User Error Abend <xxxx>, Reason=<dddd/hhhh>, TBLBASE Initializing

Abend code G200 indicates a CICS environment; 0200 indicates otherwise. For more information, call DataKinetics Technical Support.

DK100411E

TSR Create failed: Failed by site IEFUSI

Contact DataKinetics Technical Support for assistance.

DK100412E

TSR Create failed: MVS resource shortage

Contact DataKinetics Technical Support for assistance.

DK100413W

SNAP SUPPRESSED; GETMEM SHORTAGE

Contact DataKinetics Technical Support for assistance.

DK100414E

TSR Create failed: LDS Smaller than TSR SIZE

DK100415E

TSRACCESS=RO using empty LDS

DK100416I

TSR successfully mapped to LDS

Information only.

DK100417I

TSR successfully saved on LDS

Information only.

DK100471E

BDAM ERROR: File=<ffffffff>, Function=<xxxxxxxx>

Contact DataKinetics Technical Support for assistance.

DK100472E

VSAM ERROR: File=<ffffffff>, Function=<xxxxxxxx>, Reg15=<rrrrr>, Error Code=<xxxxx>

Contact DataKinetics Technical Support for assistance.

DK100472E

I/O ERROR: <text>

Contact DataKinetics Technical Support for assistance.

DK100472E

<xxxx> ERROR: File=<ffffffff>, Function=<xxxxxxxx>, Resp=<rrrrr>, Resp2=<pppppp> (Resp2=VSAM Response)

Contact DataKinetics Technical Support for assistance.

DK100473E

VSAM ERROR: File=<ffffffff>, Request=ATTR2, Retcode=<xxx>, Reason=<yyy>, R15=<zzz> DSNAME=<dsname>

Contact DataKinetics Technical Support for assistance.

DK100476E

xxAM ERROR: FUNCTION=<xxxxxxxx>,FILE=<ffffffff>

Contact DataKinetics Technical Support for assistance.

DK100477E

I/O ERROR: <text>

Contact DataKinetics Technical Support for assistance.

DK100477E

VSAM ERROR: FUNCTION=<xxxxxxxx>,​REG15=<rrrrr>,​ERROR CODE=<xxxxx>,​FILE=<ffffffff>

Contact DataKinetics Technical Support for assistance.

DK100490E

ERROR ON TBDEBUG FILE, REASON=<xxxx>, DEBUG DISABLED

Contact DataKinetics Technical Support for assistance.

DK100494E

Persistent Task ended before end of step

Contact DataKinetics Technical Support for assistance.

DK100495I

IN ROTBVTSD

Information only.

DK100496E

Multitasking requires TBOPT Multitasking=Y be set

Reset MULTITASKING parameter in TBOPT

DK100497E

failed to delete ESTAE

Contact DataKinetics Technical Support for assistance.

DK100501S

EXEC CICS FAILURE: <xxxxxxxx> Resp=<cccc/hhhhhhhh>, Resp2=<cccc/hhhhhhhh>

Contact DataKinetics Technical Support for assistance.

DK100511E

TSR Create failed: Failed by site IEFUSI

Contact DataKinetics Technical Support for assistance.

DK100512E

TSR Create failed: MVS resource shortage

Contact DataKinetics Technical Support for assistance.

DK100513W

SNAP suppressed; GETMEM shortage

Contact DataKinetics Technical Support for assistance.

DK100530I

No storage for QTCWA; QCT function not used.

Information only.

DK100531I

Module DK1TRSTA not found; QCT function not used.

Information only.

DK100532I

Attaching QCT x

Information only.

DK100533I

QCT X Detached

Information only.

DK100550I

tableBASE <version> – Resource manager initializing

Information only.

DK100551I

tableBASE Resource manager initialized

Information only.

DK100552E

tableBASE Initialization Error

Contact DataKinetics Technical Support for assistance.

DK100553I

tableBASE Initialization Failed

Information only.

DK100554I

tableBASE Starting tblBASE

Information only.

DK100555I

tableBASE tblBASE started

Information only.

DK100556I

tableBASE Deactivating

Information only.

DK100557I

tableBASE Deactivated

Information only.

DK100558E

tableBASE Deactivation Error

Contact DataKinetics Technical Support for assistance.

DK100559I

tableBASE Deactivation Failed

Information only.

DK100560I

tableBASE Restarting

Information only.

DK100561I

tableBASE Verifying

Information only.

DK100562I

tableBASE Verify completed

Information only.

DK100563I

tableBASE – Error Info: Func(<functionname>/<subfunctionname>) Resp(<responsecode>) Resp2(<responsecode>)

This is error information received by tableBASE when requesting a CICS service function. Refer to the CICS manuals as required.

DK100564I

DK1TCIN used in PLT takes one of TBINIT (default) or INIT.

Information only.

DK100565I

Successful <xxxx> INIT must be done before <xxxx> TBCALL

Information only.

DK100566I

Verification failure

Information only.

DK100567E

The tableBASE PC Server must be running for tableBASE to initialize.

The tableBASE PC Server is not running. It must be running in order for tableBASE to initialize in CICS regions.

DK100568E

Program DK1TCIN must be defined as CONCURRENCY(QUASIRENT)

Define DK1TCIN as per message and try again.

DK100569E

Module DK1CBASE must be current to determine version.

Contact DataKinetics Technical Support for assistance.

DK100570I

<xxxx> takes TBINIT or TERM as a parameter

Information only.

DK100571I

Phase in of <xxxxxxxx> not allowed by CICS; current in-storage copy used.

Information only.

DK100572I

<xxxxxxxx> LP=<xxxxxxxx> EP=<xxxxxxxx> AM=<xx> RC=<xxxxxxxx> UC=<xxxxxxxx>

Information only.

DK100573I

Module <xxxxxxxx> not loaded

Information only.

DK100574I

Module <xxxxxxxx> not found.

Information only.

DK100575I

EX=<xxxxxxxx> EN=<xxxxxxxx> STST=<xxxx> SHST=<xxxx> TAST=<xxxx> TALN=<xxxxx> GALN=<xxxxx>

Information only.

DK100576I

<xxxxxxxxxxxxxxxx/xxxxxxxx> OK

Information only.

DK100577I

<xxxxxxxx> LP=<xxxxxxxx> EP=<xxxxxxxx> LEN=<xxxxxxxx> AM=<xxx> KEY=<x>

Information only.

DK100578I

tableBASE – Shutdown Completed.

Information only.

DK100579I

tableBASE – Shutdown Aborted: Internal Resource Anchor Block (RCABLK) not found.

Information only. Contact DataKinetics Technical Support for further information about this message.

DK100580I

tableBASE – Shutdown Aborted: TRUE TBASECRM not enabled.

Information only. Contact DataKinetics Technical Support for further information about this message.

DK100590E

TBL BASE ERROR DEBUG WTD, REASON=<xxxx>, DEBUG DISABLED

Contact DataKinetics Technical Support for assistance.

DK100595I

Trans error dump taken. Dumpcode is DKL1. Dumpid is <xxxxxxxx>

Information only.

DK100596E

CICS Assign failed (Resp/Resp2=<nnnnn/nnnnn>); dump suppressed

Contact DataKinetics Technical Support for assistance.

DK100597E

CICS DUMP TRANSACTION failed (Resp/Resp2=<nnnnn/nnnnn>). Dump for userid <xxxxxxxx> not taken.

Contact DataKinetics Technical Support for assistance.

DK100600I

tableBASE V<vrm> VTS <xxxxxxxx> initialized

Information only.

DK100601E

GCA cannot be located; VTS stopping

The tableBASE PC Server is not running. It must be running before any VTS-TSRs can be brought up.

DK100602E

VTS Agent incompatible with GCA structure

Contact DataKinetics Technical Support for assistance.

DK100603E

Duplicate VTS attempting to start; auto-stopping

Another VTS with the same name is already running.

DK100604E

Program <xxxxxxxx> is not APF authorized

The program must be APF authorized to run this task.

DK100605E

V<vrm> Environment not ready; VTS stopping

Neither the tableBASE PC Server nor compat VTS Group Manager are running. Either one must be running before any VTS-TSRs can be brought up.

DK100606E

Incompatible DK1VBASE; VTS stopping

The version of DK1VBASE is not compatible with this release.

DK100608E

Not authorized to start VTS resource: <vtsresourcename>

This userid is not authorized to start the VTS resource named due to lack of RACF authorization. A minimum of CONTROL access is required to start a RACF-protected VTS.

DK100610E

Error in <xxxxxxxx> macro; RC/REASON=<xxx/yyyy>

Contact DataKinetics Technical Support for assistance.

DK100620E

VTS is running in a Non-level 8 GCA

Contact DataKinetics Technical Support for assistance.

DK100629E

Invalid non-level 8 GCA

Contact DataKinetics Technical Support for assistance.

DK100630I

Console interface is available

Information only.

DK100631E

Invalid command; command ignored

The command supplied is invalid.

DK100632W

‘REFRESH not supported in tableBASE <vv> VTS

The RF command is not supported in VTS.

DK100633I

SHUTDOWN

Information only.

DK100634I

STOP command received, V<vrm> VTS <xxxxxxxx> terminating

Information only.

DK100636W

switching TSRACCESS to RW, VTS <xxxxxxxx>: <nnnn> users may be affected

Warning message.

DK100637W

TSRACCESS=RW forced RO for locking-<xxxxxxxx>

Warning that the TSR access mode has been force switched to RO.

DK100638W

switching TSRACCESS to RO, VTS <xxxxxxxx>: <nnnn> users may be affected

Warning message.

DK100639E

Not authorized to stop VTS resource: <vtsresourcename>

This userid is not authorized to stop the VTS resource named due to lack of RACF authorization. A minimum of CONTROL access is required to stop a RACF-protected VTS.

DK100701S

tableBASE PC Server unavailable, required for license options

The tableBASE PC Server must be running.

DK100702I

TSR size reset to LDS size

Applicable only for VTS Manager.

DK100703S

Invalid LDSTSR dataset

Applicable only for VTS Manager.

DK100704W

TSRACCESS forced to RO: LDSTSR DISP=SHR

Due to the disposition of the LDS dataset, the TSR access mode is forced to RO. Applicable only for VTS Manager.

DK100705I

MAXNMTAB ignored for TSRACCESS=RO

Applicable only for VTS Manager.

DK100706W

SYSPLEX=Y incompatible with TSRACCESS=RW; TSRACCESS set to RO

Applicable only for VTS Manager.

DK100707E

TPVM incompatible with COMPAT VTS Agent

Applicable only for VTS Manager.

DK100708I

StrobeMethod 3 allowed only for VTS

Information only.

DK100709E

StrobeMethod 3 required for VTS with non-zero TSR_KEY-PROTECT

When a VTS is hardware key-protected, TBOPT option STROBEMETHOD=3 must be used.

DK100710W

TSRACCESS forced to RO: TSR_KEY_PROTECT set

Warning message. A hardware key-protected VTS can only be started up in read-only mode.

DK100800I

tableBASE PC server V<vrm> available

The tableBASE PC Server is now running. It must be running in order for tableBASE to initialize in batch jobs, CICS regions, IMS regions, DB2 SPAs and VTS-TSRs.

DK100802E

PC server <xxxxxxxx> terminating; see message DK100803I for reason.

Contact DataKinetics Technical Support for assistance.

DK100803I

<variable length message text>

Information only.

DK100804S

System must support 64-bit architecture

Starting with Version 7, tableBASE requires z/OS running on 64-bit hardware which supports the General Instructions Extension Facility (GIEF), the Long Displacement Facility, the Extended-immediate Facility and the Execute-extensions Facility. These are provided with the Z10-EC processor or higher.

DK100805W

License checking error <nnn> for <pppppppp>

The license checker encountered an error. Contact DataKinetics Technical Support for assistance.

DK100806W

Error <nnn>-<rrr> LOADing DK1TLICK; <pppppppp> not licensed

Error loading the license checker. Contact DataKinetics Technical Support for assistance.

DK100807W

Error <nnn> ATTACHing DK1TLICK for <pppppppp>

Error attaching the license checker. Contact DataKinetics Technical Support for assistance.

DK100811I

Invalid command; ignored: <cccccccc>

Information only.

DK100812I

STOP command received

Information only.

DK100820W

DK1TPC01/DK1TLICK interface mismatch <nnn/nnn>

Contact DataKinetics Technical Support for assistance.

DK100821W

PC Server <vvvv> does not support <pppppppp>

Contact DataKinetics Technical Support for assistance.

DK100822W

<pppppppp> not supported by licensing routine

Contact DataKinetics Technical Support for assistance.

DK100823W

DK1TLICK not authorized to enter key 0

Contact DataKinetics Technical Support for assistance.

DK100824W

PC Server <vvvv> not found

Ensure that the PC Server for this release is running.

DK100825W

Licensing subroutine returned RC=<rrrrr>

Contact DataKinetics Technical Support for assistance.

DK100826W

<pppppppp> license expired <yyyy-mm-dd>; in grace period

The license for the named product has expired and it is now running in the grace period. It will stop functioning after the grace period.

DK100827W

<pppppppp> license expired <yyyy-mm-dd>

The license for the named product has expired and the product has stopped functioning.

DK100828W

<pppppppp> license will expire <yyyy-mm-dd>

The named product is in the warning period for its license and will no longer be licensed on the specified date.

DK100829W

<pppppppp> license expires today <yyyy-mm-dd>

Just after midnight today, the named product will no longer be licensed. If there is a grace period, the product will continue to function during that period.

DK100830W

<pppppppp> license module DK1xBASE missing

The license module specified for the named product is missing.

DK100831W

<pppppppp> DK1xBASE <vvvv> mismatch <vvvv>

The license module specified for the named product is for a different version.

DK100832W

<pppppppp> DK1xBASE return code <rrrr>

Contact DataKinetics Technical Support for assistance.

DK100833I

<pppppppp> licensed to <customer>

Information only.

DK100844S

Customer Anchor Table DKL slot invalid: RC=<r>.

Contact DataKinetics Technical Support for assistance.

DK100847S

cannot start, too many DKL products

Contact DataKinetics Technical Support for assistance.

DK100848S

TPM may be running, run DK1PTERM

Applicable only for VTS Manager.

DK100849S

Replacing corrupted GCA

Contact DataKinetics Technical Support for assistance.

DK100850I

deleting NT

Information only.

DK100851I

NT deleted

Information only.

DK100852I

freeing PC code

Information only.

DK100853I

PC code freed

Information only.

DK100854I

Freeing GCA

Information only.

DK100855I

Freeing GCAX

Information only.

DK100856I

GCA purged

Information only.

DK100857I

Replacing corrupted Dummy TPM block

Information only.

DK100858S

PC Server unable to obtain storage

Contact DataKinetics Technical Support for assistance.

DK100859I

Completing Dummy TPM/TPV blocks

Information only.

DK100870W

LXFRE Bad Return Code

Contact DataKinetics Technical Support for assistance.

DK100871S

$DOPC GETMAIN Failed

Contact DataKinetics Technical Support for assistance.

DK100872E

LXFREE Getmain Failed

Contact DataKinetics Technical Support for assistance.

DK100873W

LXFREE Freemain Failed

Contact DataKinetics Technical Support for assistance.

DK100874S

$DOPC SCHEDIRB Macro Failed

Contact DataKinetics Technical Support for assistance.

DK100875S

$DOPC DK1TPC11 Routine Failed

Contact DataKinetics Technical Support for assistance.

DK100876S

$DOPC LOADROTB Service Failed

Contact DataKinetics Technical Support for assistance.

DK100877I

DK1TVROT Named Token Failed

Information only.

DK100900S

Not licensed for VTS Manager options

Your installation is not licensed for this feature. Contact DataKinetics Technical Support for further information.

DK100901S

Not licensed for VTS Gate options

Your installation is not licensed for this feature. Contact DataKinetics Technical Support for further information.

DK100902S

Not licensed for DEFAULT_TSR options

Your installation is not licensed for this feature. Contact DataKinetics Technical Support for further information.

DK100990S

Incompatible ROOT and NUCLEUS versions

Contact DataKinetics Technical Support for assistance.

DK100991E

Parms module not loaded

Contact DataKinetics Technical Support for assistance.

DK100993E

Parms module corrupted

Contact DataKinetics Technical Support for assistance.