Command Interpretation Errors

Command interpretation errors are detected during the parsing of command sequences. When a command interpretation error occurs, an error message is issued and DK1MEXEC proceeds with the next command sequence.

Table 59. Command Interpretation messages
Message Description Action
End of data – DK1MEXEC Utility ended Informational
Delimiter is invalid, = is expected An equal sign (=) must follow the keyword in the parameter
Command is invalid The command is not recognized
Keyword is invalid The Keyword is not recognized
xxxxxxxx … field is greater than 8 characters xxxxxxx is the first eight characters of the field that is too long
Semi-colon is missing from the command Place a semi-colon at the end of each command sequence
Keyword is incomplete
Keyword is invalid for this combination
Required Keyword missing for this command
Duplicate Keyword for this command A valid keyword was specified more than once in a command sequence. This is not
allowed.
Invalid name specified Alias and VTS names must be one to eight characters. The first character must
be alphabetic or one of the national characters @, $, or #. Remaining characters
must be alphabetic, numeric or one of the national characters @, $, or #.
COMMAND REJECTED FOR ABOVE REASON Informational. One or more previous messages describe the error.
SHOW REQUEST COMPLETED Informational
DEFAULTS SET SUCCESSFULLY Informational
DK1MEXEC INTERNAL PROGRAM ERROR Contact DataKinetics technical support for assistance.
SERIOUS ERROR. DK1MEXEC IS ABENDING Contact DataKinetics technical support for assistance.